, , ,

Dell PowerEdge R960


Maximize transformation and data-driven initiatives with extreme scale-up capabilities, for superior workload density and performance.

Pretul afisat contine TVA (21%).

PowerEdge R960

Maximize transformation and data-driven initiatives with extreme scale-up capabilities, for superior workload density and performance.

Key Features

Maximum performance for your business

Maximize transformation and data-driven initiatives with extreme scale-up capabilities, for superior workload density and performance.

Specifications

Processor Up to 4 x 4th Generation Intel Xeon Scalable processor with up to 60 cores per processor and with optional Intel®QuickAssist Technology
Operating System Canonical®Ubuntu®Server LTS
Microsoft®Windows Server®with Hyper-V
RedHat®Enterprise Linux
SUSE Linux Enterprise Server
VMware®ESXi®
Chipset Intel®C741 Chipset
Accelerators Up to 4 x 400 W DW
Memory DIMM Speed Up to 4800 MT/s
Memory Type RDIMM
Memory Module Slots 64 DDR5 DIMM slots
Maximum RAM RDIMM 16 TB
Storage Front Bay
Up to 8 x 2.5-inch SAS/SATA (HDD/SSD) max 122.88 TB
Up to 16 x 2.5-inch SAS/SATA (HDD/SSD) max 245.76 TB
Up to 24 x 2.5-inch NVMe (SSD) max 368.64 TB
Up to 16 x 2.5-inch SAS/SATA (HDD/SSD) + 8 x 2.5-inch NVMe (SSD) max 368.64 TB
Up to 32 x 2.5-inch SAS/SATA max 491.52 TB
Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) max 122.88 TB
Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) + 8 x 2.5-inch SAS/SATA (HDD/SSD) max 245.76 TB
Storage Controllers Internal Controllers PERC H965i, PERC H755, PERC H355, HBA355i
External Controllers HBA355e
Software RAID S160
Internal Boot Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs
USB
Security Cryptographically signed firmware
Data at Rest Encryption (SEDs with local or external key mgmt)
Secure Boot
Secure Erase
Secured Component Verification (Hardware integrity check)
Silicon Root of Trust
System Lockdown (requires iDRAC9 Enterprise or Datacenter)
TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ
Management Embedded / At-the-Server
iDRAC9
iDRAC Direct
iDRAC RESTful API with Redfish
iDRAC Service Module
Quick Sync 2 wireless module
Consoles
OpenManage Enterprise
OpenManage Power Manager plugin
OpenManage Service plugin
OpenManage Update Manager plugin
CloudIQ for PowerEdge plug in
OpenManage Enterprise Integration for VMware®vCenter™
OpenManage Integration for Microsoft®System Center
OpenManage Integration with Windows Admin Center
Mobility
OpenManage Mobile
Tools
Dell Repository Manager
Dell System Update
Enterprise Catalogs
iDRAC RESTful API with Redfish
IPMI
RACADM CLI
OpenManage Integrations
BMC Truesight
Microsoft®System Center
OpenManage Integration with ServiceNow
RedHat®Ansible®Modules
Terraform Providers
VMware®vCenter™ and vRealize Operations Manager
Ports Network Options
1 x 1GbE LOM card (optional)
1 x OCP card 3.0 (optional)
Note: The system allows either LOM card or an OCP card or both to be installed in the system.
Front Ports
1 x iDRAC Direct (Micro-AB USB) port
1 x USB 2.0
1 x VGA
Rear Ports
1 x Dedicated iDRAC Ethernet port
1 x USB 2.0
1 x USB 3.0
1 x Serial (optional)
1 x VGA (optional for Direct Liquid Cooling configuration)
Internal ports
1 x USB 3.0 (optional)
Slots 12 PCIe slots:
Slot 1: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length
Slot 2: 1 x16 Gen5 Full height, Half length
Slot 3: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 4: 1 x16 Gen5 Low profile, Half length
Slot 5: 1 x16 Gen5 Full height, Half length
Slot 6: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 7: 1 x16 Gen5 Full height, Half length
Slot 8: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 9: 1 x16 Gen5 Low profile, Half length
Slot 10: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length
Slot 11: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 12: 1 x16 Gen5 Full height, Half length
Bezel Optional LCD bezel or security bezel
Form Factor 4U rack server
Dimensions & Weight Height
6.86 in. (174.30 mm)
Width
18.97 in. (482.00 mm)
Depth
34.77 in. (883.19 mm) with bezel
34.22 in. (869.19 mm) without bezel
Weight
132.71 lb (Max 60.20 kg)
Combo (Drop-in/Slide-in) rails with optional CMA and SRB for 4-post racks.
Note: CMA is not supported in Direct Liquid Cooling configuration
Recommended Support Choose Dell ProSupport Plus for critical systems or Dell ProSupport for premium hardware and software support for your PowerEdge solution. Consulting and deployment offerings are also available. Contact your Dell representative today for more information. Availability and terms of Dell Services vary by region.
Regulatory Product Safety and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment
SKU: poweredge-r960 Categorii: , , ,
Processor Up to 4 x 4th Generation Intel Xeon Scalable processor with up to 60 cores per processor and with optional Intel®QuickAssist Technology
Operating System Canonical®Ubuntu®Server LTS
Microsoft®Windows Server®with Hyper-V
RedHat®Enterprise Linux
SUSE Linux Enterprise Server
VMware®ESXi®
Chipset Intel®C741 Chipset
Accelerators Up to 4 x 400 W DW
Memory DIMM Speed Up to 4800 MT/s
Memory Type RDIMM
Memory Module Slots 64 DDR5 DIMM slots
Maximum RAM RDIMM 16 TB
Storage Front Bay
Up to 8 x 2.5-inch SAS/SATA (HDD/SSD) max 122.88 TB
Up to 16 x 2.5-inch SAS/SATA (HDD/SSD) max 245.76 TB
Up to 24 x 2.5-inch NVMe (SSD) max 368.64 TB
Up to 16 x 2.5-inch SAS/SATA (HDD/SSD) + 8 x 2.5-inch NVMe (SSD) max 368.64 TB
Up to 32 x 2.5-inch SAS/SATA max 491.52 TB
Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) max 122.88 TB
Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) + 8 x 2.5-inch SAS/SATA (HDD/SSD) max 245.76 TB
Storage Controllers Internal Controllers PERC H965i, PERC H755, PERC H355, HBA355i
External Controllers HBA355e
Software RAID S160
Internal Boot Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs
USB
Security Cryptographically signed firmware
Data at Rest Encryption (SEDs with local or external key mgmt)
Secure Boot
Secure Erase
Secured Component Verification (Hardware integrity check)
Silicon Root of Trust
System Lockdown (requires iDRAC9 Enterprise or Datacenter)
TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ
Management Embedded / At-the-Server
iDRAC9
iDRAC Direct
iDRAC RESTful API with Redfish
iDRAC Service Module
Quick Sync 2 wireless module
Consoles
OpenManage Enterprise
OpenManage Power Manager plugin
OpenManage Service plugin
OpenManage Update Manager plugin
CloudIQ for PowerEdge plug in
OpenManage Enterprise Integration for VMware®vCenter™
OpenManage Integration for Microsoft®System Center
OpenManage Integration with Windows Admin Center
Mobility
OpenManage Mobile
Tools
Dell Repository Manager
Dell System Update
Enterprise Catalogs
iDRAC RESTful API with Redfish
IPMI
RACADM CLI
OpenManage Integrations
BMC Truesight
Microsoft®System Center
OpenManage Integration with ServiceNow
RedHat®Ansible®Modules
Terraform Providers
VMware®vCenter™ and vRealize Operations Manager
Ports Network Options
1 x 1GbE LOM card (optional)
1 x OCP card 3.0 (optional)
Note: The system allows either LOM card or an OCP card or both to be installed in the system.
Front Ports
1 x iDRAC Direct (Micro-AB USB) port
1 x USB 2.0
1 x VGA
Rear Ports
1 x Dedicated iDRAC Ethernet port
1 x USB 2.0
1 x USB 3.0
1 x Serial (optional)
1 x VGA (optional for Direct Liquid Cooling configuration)
Internal ports
1 x USB 3.0 (optional)
Slots 12 PCIe slots:
Slot 1: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length
Slot 2: 1 x16 Gen5 Full height, Half length
Slot 3: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 4: 1 x16 Gen5 Low profile, Half length
Slot 5: 1 x16 Gen5 Full height, Half length
Slot 6: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 7: 1 x16 Gen5 Full height, Half length
Slot 8: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 9: 1 x16 Gen5 Low profile, Half length
Slot 10: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length
Slot 11: 1 x16 Gen5 Full height, Half length or 1 x16 Gen5 Full height, Full length (double width)
Slot 12: 1 x16 Gen5 Full height, Half length
Bezel Optional LCD bezel or security bezel
Form Factor 4U rack server
Dimensions & Weight Height
6.86 in. (174.30 mm)
Width
18.97 in. (482.00 mm)
Depth
34.77 in. (883.19 mm) with bezel
34.22 in. (869.19 mm) without bezel
Weight
132.71 lb (Max 60.20 kg)
Combo (Drop-in/Slide-in) rails with optional CMA and SRB for 4-post racks.
Note: CMA is not supported in Direct Liquid Cooling configuration
Recommended Support Choose Dell ProSupport Plus for critical systems or Dell ProSupport for premium hardware and software support for your PowerEdge solution. Consulting and deployment offerings are also available. Contact your Dell representative today for more information. Availability and terms of Dell Services vary by region.
Regulatory Product Safety and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Dell PowerEdge R960”

There are no reviews yet.

Completeaza formularul de mai jos si te vom contacta cu o oferta personalizata.

Configuratie dorita

Completeaza formularul de mai jos si te vom contacta pentru publicarea in SICAP.

Select at least 2 products
to compare